Class I Biological Safety Cabinet
Class I Biological Safety Cabinet
Laminar flow clean bench designed to provide a sterile working environment with consistent airflow and high-efficiency filtration for sample protection.
Description
| Specification | BYKG-I | BYKG-II | BYKG-III | BYKG-V |
|---|---|---|---|---|
| External Size (W×D×H) | 550 × 395 × 730 mm | 700 × 550 × 900 mm | 900 × 713 × 1250 mm | 1100 × 695 × 1924 mm |
| Internal Size (W×D×H) | 540 × 385 × 440 mm | 680 × 540 × 500 mm | 800 × 635 × 600 mm | 968 × 695 × 630 mm |
| HEPA Filter | 99.999% efficiency at 0.3 μm | 99.999% efficiency at 0.3 μm | 99.999% efficiency at 0.3 μm | 99.999% efficiency at 0.3 μm |
| Airflow Velocity | ≥0.3 m/s | 0.75–1.0 m/s | ≥0.3 m/s | 0.75–1.0 m/s |
| Noise | ≤60 dB | ≤55 dB | ≤60 dB | ≤67 dB |
| Illuminating Lamp | 4W × 1 | 8W × 1 | 8W × 1 | 21W × 2 |
| Illuminating Lamp | LED Lamp | LED Lamp | LED Lamp | Fluorescent lamp |
| UV Lamp | 15W × 1 | 20W × 1 | 20W × 1 | 20W × 1 |
| UV Lamp | Emission of 253.7 nanometers for most efficient decontamination | Emission of 253.7 nanometers for most efficient decontamination | Emission of 253.7 nanometers for most efficient decontamination | Emission of 253.7 nanometers for most efficient decontamination |
| UV Lamp | BYKG-III has UV timer function and the display could indicate the UV life. | BYKG-III has UV timer function and the display could indicate the UV life. | BYKG-III has UV timer function and the display could indicate the UV life. | BYKG-III has UV timer function and the display could indicate the UV life. |
| Power Consumption | 150 W | ≤160 W | ≤400 W | ≤350 W |
| Work Surface Height | / | / | / | 750 mm |
| Caster | / | / | / | Universal caster |
| Main Body Construction | PMMA | PMMA | Cold-rolled steel with anti-bacteria powder coating | Cold-rolled steel with anti-bacteria powder coating |
| Work Table | 304 stainless steel | 304 stainless steel | 304 stainless steel | 304 stainless steel |
| Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
| Standard Accessory | LED lamp, UV lamp ×2 | LED lamp, UV lamp ×2 | LED lamp, UV lamp ×2 | Fluorescent lamp, UV lamp ×2, Base stand |
| Optional Accessory | Electric height adjustable base stand | Electric height adjustable base stand | Electric height adjustable base stand | Electric height adjustable base stand |
| Gross Weight | 38 kg | 68 kg | 147 kg | 185 kg |
| Package Size (W×D×H) | 710 × 550 × 950 mm | 870 × 720 × 1170 mm | 1060 × 870 × 1440 mm | 1270 × 880 × 2230 mm |
- UV lamp for sterilization.
- Soft touch control panel, LCD display.
- Energy-saving, high efficiency, low noise.
- With memory function in case of power-failure.
- One piece 304 stainless steel work stable, easy for cleaning.
- Stable air flow system; protecting to person and environment.
Request a Quote Today
Tell us your requirements and our team will get back to you with a tailored solution, pricing, and expert support.
Answers to Common Fume Hood Questions
Quick guidance to help you choose the right fume hood for your lab or facility.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.