| Specification | BSC-3FA2 (3′) | BSC-4FA2 (4′) |
|---|---|---|
| External Size (W×D×H) | 1087 × 775 × 2265 mm | 1383 × 775 × 2295 mm |
| Internal Size (W×D×H) | 910 × 600 × 660 mm | 1210 × 600 × 660 mm |
| Work Surface Height | 750 mm | 750 mm |
| Max Opening | 520 mm (21″) | 550 mm (22″) |
| Tested Opening | Safety height 200 mm (8″) | Safety height 200 mm (8″) |
| Airflow Volume – Inflow | 348 m³/h (205 cfm) | 462 m³/h (272 cfm) |
| Airflow Volume – Down flow | 65%: 649 m³/h (382 cfm) | 65%: 863 m³/h (507 cfm) |
| Airflow Volume – Exhaust | 35%: 348 m³/h (205 cfm) | 35%: 462 m³/h (272 cfm) |
| Front Window | Manual. Two-layer laminated toughened glass ≥5mm. Anti UV | Manual. Two-layer laminated toughened glass ≥5mm. Anti UV |
| HEPA Filter | Two, 99.999% efficiency at 0.3um, filter life indicator | Two, 99.999% efficiency at 0.3um, filter life indicator |
| Filter Guard Type | Aluminum alloy frame | Aluminum alloy frame |
| Noise | NSF 49≤61 dB / EN 12469≤58 dB | NSF 49≤61 dB / EN 12469≤58 dB |
| Illumination | ≥1000 Lux | ≥1000 Lux |
| Display | LCD Display | LCD Display |
| Waterproof Socket | 2, Total consumption: ≤500W | 2, Total consumption: ≤500W |
| Tap | Water tap ×1, Gas tap ×1 | Water tap ×1, Gas tap ×1 |
| Ground Resistance | ≤ 0.10 Ω | ≤ 0.10 Ω |
| Power Supply | AC230V, 50Hz | AC230V, 50Hz |
| Consumption | ≤500W | ≤600W |
| Alarm | Abnormal airflow velocity; Filter replacement; Front window at unsafe height | Abnormal airflow velocity; Filter replacement; Front window at unsafe height |
- Large LCD display, all information displayed.
- Automatic air speed adjustable with filter block.
- With memory function in case of power-failure.
- Side & back wall is made up of single piece stainless steel.
- Interlock function: UV lamp and front window; UV lamp and blower, fluorescent lamp; Blower and front window.
- Front 10°slanted to offer operator comfort while working for long time, reduce glare and maximize reach into the work area.
Request a Quote Today
Tell us your requirements and our team will get back to you with a tailored solution, pricing, and expert support.
Answers to Common Fume Hood Questions
Quick guidance to help you choose the right fume hood for your lab or facility.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.