Class III Biological Safety Cabinet

Class III Biological Safety Cabinet

Class III Biosafety Cabinet is totally enclosed and gas-tight, it also can meet the requirement of operating Class I, II, III, IV pathogenic factor. It can be used in P3,P4 laboratory.

Description

Class III Biosafety Cabinet is totally enclosed and gas-tight, it also can meet the requirement of operating Class I, II, III, IV pathogenic factor. It can be used in P3,P4 laboratory.
SpecificationBSC-1100IIIXBSC-1500IIIX
External Size (W×D×H)1540 × 880 × 2000 mm1790 × 880 × 2080 mm
Internal Size (W×D×H)910 × 650 × 660 mm1165 × 650 × 660 mm
Pass Box Size (W×D×H)Internal Size: 430 × 330 × 355 mm External Size: 575 × 425 × 495 mmInternal Size: 430 × 330 × 355 mm External Size: 575 × 425 × 495 mm
GlovesOne pair of 800mm butyl rubber glovesOne pair of 800mm butyl rubber gloves
Front Window8 mm toughened glass, anti-ultraviolet radiation8 mm toughened glass, anti-ultraviolet radiation
DisplayLCD displayLCD display
Pre-filterPolyester fiber, washablePolyester fiber, washable
Pressure≥ negative 120 Pa≥ negative 120 Pa
ULPA FilterAir supply filter: Efficiency 99.9995% at 0.12μm First exhaust filter: Efficiency 99.9995% at 0.12μm Second exhaust filter: Efficiency 99.9995% at 0.12μmAir supply filter: Efficiency 99.9995% at 0.12μm First exhaust filter: Efficiency 99.9995% at 0.12μm Second exhaust filter: Efficiency 99.9995% at 0.12μm
NoiseNSF 49 ≤61 dB / EN 12469 ≤48 dBNSF 49 ≤61 dB / EN 12469 ≤48 dB
AlarmAudio and visual alarm, abnormal pressure; filter replacementAudio and visual alarm, abnormal pressure; filter replacement
Work Zone Material304 stainless steel304 stainless steel
Illumination≥ 1000 lux≥ 1000 lux
Consumption1200 W1300 W
LED Lamp12W × 216W × 2
UV Lamp18W × 2, 8W × 1 Emission of 253.7 nanometers for most efficient decontamination30W × 2, 8W × 1 Emission of 253.7 nanometers for most efficient decontamination
Power SupplyAC220V±10%, 50/60Hz; 110V±10%, 60HzAC220V±10%, 50/60Hz; 110V±10%, 60Hz
Gross Weight350 kg450 kg
Package Size (W×D×H)1635 × 1062 × 2160 mm1890 × 1065 × 2240 mm
Standard AccessoriesGloves, fluorescent lamp, UV lamp ×4, remote control, pressure meter, drain valveGloves, fluorescent lamp, UV lamp ×4, remote control, pressure meter, drain valve
Class III Biosafety Cabinet is totally enclosed and gas-tight with ULPA filtered supply and exhaust air. Work is performed with long-sleeved gloves. The cabinet is kept under negative pressure of at least 120Pa, and airflow is maintained by a dedicated exterior exhaust system. It can protect the operator, product and environment.
FeatureDetails
Pass BoxDouble doors with interlock function and UV lamp.
Pressure MeterDisplay the pressure of work zone.
UV LampEmission of 253.7 nanometers for most parameters efficient decontamination.
LCD DisplayLarge display is easy to monitor the pressure for work zone and three filters.
ADVANTAGE
  • With memory function in case of power-failure.
  • UV lamp ensures work area sterilization effectively.
  • An angled cabinet front ensure an ergonomic working posture.
  • Exhaust air is double-filtered through high-quality ULPA filters with typical efficiency of 99.9995% for 0.12μmparticles.

Request a Quote Today

Tell us your requirements and our team will get back to you with a tailored solution, pricing, and expert support.

Answers to Common Fume Hood Questions

Quick guidance to help you choose the right fume hood for your lab or facility.

Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.

Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.

Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.

Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.

Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.

Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.

Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.

Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.

Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.

Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.

error: Content is protected !!