Class III Biological Safety Cabinet
Class III Biological Safety Cabinet
Class III Biosafety Cabinet is totally enclosed and gas-tight, it also can meet the requirement of operating Class I, II, III, IV pathogenic factor. It can be used in P3,P4 laboratory.
Description
| Specification | BSC-1100IIIX | BSC-1500IIIX |
|---|---|---|
| External Size (W×D×H) | 1540 × 880 × 2000 mm | 1790 × 880 × 2080 mm |
| Internal Size (W×D×H) | 910 × 650 × 660 mm | 1165 × 650 × 660 mm |
| Pass Box Size (W×D×H) | Internal Size: 430 × 330 × 355 mm External Size: 575 × 425 × 495 mm | Internal Size: 430 × 330 × 355 mm External Size: 575 × 425 × 495 mm |
| Gloves | One pair of 800mm butyl rubber gloves | One pair of 800mm butyl rubber gloves |
| Front Window | 8 mm toughened glass, anti-ultraviolet radiation | 8 mm toughened glass, anti-ultraviolet radiation |
| Display | LCD display | LCD display |
| Pre-filter | Polyester fiber, washable | Polyester fiber, washable |
| Pressure | ≥ negative 120 Pa | ≥ negative 120 Pa |
| ULPA Filter | Air supply filter: Efficiency 99.9995% at 0.12μm First exhaust filter: Efficiency 99.9995% at 0.12μm Second exhaust filter: Efficiency 99.9995% at 0.12μm | Air supply filter: Efficiency 99.9995% at 0.12μm First exhaust filter: Efficiency 99.9995% at 0.12μm Second exhaust filter: Efficiency 99.9995% at 0.12μm |
| Noise | NSF 49 ≤61 dB / EN 12469 ≤48 dB | NSF 49 ≤61 dB / EN 12469 ≤48 dB |
| Alarm | Audio and visual alarm, abnormal pressure; filter replacement | Audio and visual alarm, abnormal pressure; filter replacement |
| Work Zone Material | 304 stainless steel | 304 stainless steel |
| Illumination | ≥ 1000 lux | ≥ 1000 lux |
| Consumption | 1200 W | 1300 W |
| LED Lamp | 12W × 2 | 16W × 2 |
| UV Lamp | 18W × 2, 8W × 1 Emission of 253.7 nanometers for most efficient decontamination | 30W × 2, 8W × 1 Emission of 253.7 nanometers for most efficient decontamination |
| Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
| Gross Weight | 350 kg | 450 kg |
| Package Size (W×D×H) | 1635 × 1062 × 2160 mm | 1890 × 1065 × 2240 mm |
| Standard Accessories | Gloves, fluorescent lamp, UV lamp ×4, remote control, pressure meter, drain valve | Gloves, fluorescent lamp, UV lamp ×4, remote control, pressure meter, drain valve |
| Feature | Details |
|---|---|
| Pass Box | Double doors with interlock function and UV lamp. |
| Pressure Meter | Display the pressure of work zone. |
| UV Lamp | Emission of 253.7 nanometers for most parameters efficient decontamination. |
| LCD Display | Large display is easy to monitor the pressure for work zone and three filters. |
- With memory function in case of power-failure.
- UV lamp ensures work area sterilization effectively.
- An angled cabinet front ensure an ergonomic working posture.
- Exhaust air is double-filtered through high-quality ULPA filters with typical efficiency of 99.9995% for 0.12μmparticles.
Request a Quote Today
Tell us your requirements and our team will get back to you with a tailored solution, pricing, and expert support.
Answers to Common Fume Hood Questions
Quick guidance to help you choose the right fume hood for your lab or facility.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.