Smallest Class II A2 Biological Safety Cabinet
Smallest Class II A2 Biological Safety Cabinet
Biological safety cabinet is necessary equipment in the laboratory in the search of microbiology, biomedical, DNA recombinant, animal experiment and biological products, especially in the occasion that operator need to adopt protective measure, such us medical and health, pharmacy, medical research.
Description
| Specification | Details |
|---|---|
| Model | 11231 BBC 86 |
| External Size (W×D×H) | 700 × 650 × 1230 mm |
| Internal Size (W×D×H) | 600 × 500 × 540 mm |
| Tested Opening | Safety Height 200 mm (8″) |
| Max Opening | 370 mm (15″) |
| Inflow Velocity | 0.53 ± 0.025 m/s |
| Downflow Velocity | 0.33 ± 0.025 m/s |
| HEPA Filter | Two filters, 99.995% efficiency at 0.3 µm, with filter life indicator |
| Front Window | Motorized, toughened glass, anti-UV |
| Noise | EN1249 ≤ 58 dB / NSF49 ≤ 61 dB |
| UV Lamp | 30W × 1; UV timer, UV life indicator, 253.7 nm emission for decontamination |
| LED Lamp | 8W × 2 |
| Illumination | ≥ 1000 Lux |
| Consumption | 500 W |
| Sockets | Two sockets, total load: 500 W |
- Small dimension, save space.
- Centrifugal fan, speed adjustable; H14 HEPA filter.
- Motorized front window: The front window is motorized for convenient, one-hand operation.
- Audio and visual alarm: Abnormal airflow velocity, Filter replacement, Front window at unsafe height.
- Time reserve function: This can save 30 minutes waiting time after activating the cabinet and the sterilization time after experiment.
- Remote control: Each function can be realized 6 meters away from the cabinet by remote control, which can protect the operator under emergency.
- Large LCD display: Operators can check detailed status of the cabinet, such as inflow and downflow velocity, work area temperature and humidity, filter pressure, UV working time and filter working time, filter life indicator etc.
- With memory function in case of power-failure.
Request a Quote Today
Tell us your requirements and our team will get back to you with a tailored solution, pricing, and expert support.
Answers to Common Fume Hood Questions
Quick guidance to help you choose the right fume hood for your lab or facility.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.