Manufacturer Ducted Fume-Hood (X) For Lab
Manufacturer Ducted Fume-Hood (X) For Lab
Advanced lab features
Description
- UV lamp for sterilization.
- Motorized front glass window.
- Resistant to weak acid and alkali.
- Adjustable air speed: 9 levels.
- Alarm when filter working time 3500 hours.
- With memory function in case of power-failure.
- Back side air compensation, to avoid turbulence in work area.
- 8° slope front ergonomics design, fatigue-free working posture.
- Microprocessor control system, LEd display shows filter working time.
- Transparent side glass windows maximize light and visibility inside the cabinet, providing a bright and open working environment.
| Specification | FH1000(X) | FH1200(X) | FH1500(X) | FH1800(X) |
|---|---|---|---|---|
| External Size (W*D*H) | 1000*840*2150mm | 1200*840*2150mm | 1500*840*2150mm | 1800*840**2150mm |
| Internal Size (W*D*H) | 880*730*745mm | 1080*730*745mm | 1380*730*745mm | 1680*730*745mm |
| Max Opening | 520mm | |||
| Work Surface Height | 750mm | |||
| Blower | Built-in centrifugal blowers; Speed adjustable with 9 levels | |||
| Air Velocity | 0.3–0.8 m/s | |||
| Noise | ≤60dB | |||
| Fluorescent Lamp | 18W*1 | 36W*1 | ||
| UV Lamp | Emission of 253.7 nanometers for most efficient decontamination | |||
| Front Window | Motorized; 5 mm toughened glass, anti-UV | |||
| Material | Exterior Body: Cold-rolled steel with anti-bacteria powder coating. Work Table: Solid chemical-resistant phenolic resin | |||
| Power Supply | 220V/50Hz; 220V/60Hz; 110V/60Hz | |||
| Consumption | 400W | 500W | ||
| Standard Accessory | Water tap; Gas tap; Water sink; Base stand, UV lamp*2, Fluorescent lamp FH1000(X) with one waterproof socket not more than 500W, the other models with two waterproof sockets not more than 500W 4 meters exhaust duct Active carbon filter Foot switch | |||
| Gross Weight | 230kg | 253kg | 280kg | 340kg |
| Package Size (W*D*H) | 1230*1120*1680mm | 1350*1120*1680mm | 1650*1120*1680mm | 1950*1120*1680mm |
Request a Quote Today
Tell us your requirements and our team will get back to you with a tailored solution, pricing, and expert support.
Answers to Common Fume Hood Questions
Quick guidance to help you choose the right fume hood for your lab or facility.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.
What makes Nupon fume hoods different from others in the market?
Nupon fume hoods are built with cold-rolled steel exteriors, acid and alkali-resistant interiors, UV sterilization, and precision airflow controls. They combine durability, safety, and modern design at a competitive price — giving you big-brand quality with personalized support.
Do your fume hoods meet international safety standards?
Yes. All Nupon fume hoods are designed in compliance with international laboratory safety standards and undergo strict quality control to ensure maximum protection for operators, equipment, and the environment.
Are Nupon fume hoods customizable for specific laboratory needs?
Absolutely. We offer various sizes, airflow controls, and material options (such as chemical-resistant interiors and ergonomic slope-front designs) to suit different applications — from schools and universities to industrial facilities.
How do I maintain and clean a Nupon fume hood?
Our fume hoods are designed for easy maintenance. Regular cleaning with mild, approved cleaning agents and routine checks of the filters, airflow, and UV lamps will keep your unit performing at its best. We also provide guidance and after-sales support for proper care.
Does Nupon provide after-sales service and technical support?
Yes. We stand behind our products with dedicated after-sales service, spare parts availability, and technical support to ensure your equipment continues to deliver reliable protection long after installation.